Mounting position (angle)
Consider the following parameters when positioning the APS:
The reference plane for the mounting height is the floor directly beneath the APS. The APS can approximatively measure it's own mounting height, if there is a big enough visible floor area. Be prepared to use a distance measuring device as backup. Measure the mounting height from the base to the optics.
The APS has an integrated tilt measurement, therefore there is no need to use an extra angle measuring device. The pitch and yaw angles allow values up to 45° - keep in mind that this is not very useful, because at the camera edges you will see up to the horizon and small people may be obstructed by bigger people. 30° is a more realistic suggestion as a useful maximum.
Mounting parameters
Mounting height 2.70 .. 6.00 m
Mounting pitch angle α -45° .. 0 .. 45°
Mounting yaw angle β -45° .. 0 .. 45°
Distance from the door, optimal 30 .. 50 cm
Minimum distance to people 70 cm
Lateral alignment centered in the passage area
Monitored area (detailed information) Installation
height [m] Width (X) [m] Depth (Z) [m]
2.70 3.30 2.80
3.00 3.90 3.30
4.00 6.00 5.05
5.00 7.60 6.80
6.00 8.00 8.00
Pay attention to the dimensions of the monitored area, depending on the installation height and mounting angles.